Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Model Number : | LR-SDC-200S |
Brand Name : | Lonroy |
Price : | Negotiable |
Delivery Time : | 5-8 work days |
Supply Ability : | 200 |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union |
ISO 15989 ASTM D724 Research-Based Automatic Contact Angle Measuring Machine Test Liquid Surface Tension
1. Preface
The contact angle refers to the tangent line formed at the
intersection of gas, liquid, and solid at the gas-liquid interface.
This tangent forms an angle θ between the liquid side and the
solid-liquid boundary. Measuring the contact angle is currently the
main method for detecting surface properties. The LR-SDC-200S
research based contact angle measurement instrument utilizes
optical imaging principles and employs image contour analysis to
measure surface contact angle, wettability, interfacial tension,
forward and backward angles, surface energy, and other properties.
This device has an automatic liquid device, high
cost-effectiveness, strong scalability, and comprehensive
functions, suitable for routine measurement needs. It has been
widely used in many universities, research institutes, and
enterprises.
2. Instrument Application Field
Contact angle measuring instruments are widely used in various
fields, such as mobile phone manufacturing, glass manufacturing,
surface treatment, material research, chemical engineering,
semiconductor manufacturing, coatings and inks, electronic
circuits, textile fibers, medical biology, etc. Contact angle
measurement has become an important instrument for evaluating
surface performance. (Select special accessories for certain
testing functions)
1. The wetting behavior of the liquid on the solid surface, such as
spreading, penetration and absorption, is measured by the static
contact Angle with the droplet method;
2. Measure the forward Angle, backward Angle, contact Angle lag,
rolling Angle and dynamic contact Angle of the material on the
solid surface;
3. Continuous real-time study of absorption materials, process
record, and analysis of contact Angle curve with time;
4. Contact Angle measurement of various special materials, such as
powder, curved surface, super hydrophobic/super hydrophilic
samples;
5. Test the contact Angle of the material immersed in the liquid by
the adhesive drop method;
6. Measuring interfacial tension of various liquid surfaces and
their polarity and dispersion components by hanging drop method;
7. Calculate the Surface free energy and its polar dispersion
component;
8. Analysis of the liquid on the solid surface adhesion
(Adhersion), assessment of solid surface uniformity, cleanliness,
etc.
3. Principle
As shown in the above figure, the contact angle measuring
instrument mainly consists of a light source, an injection unit, a
sample stage, a collection system, an overall tilt platform, and
analysis software. This device adopts the principle of optical
imaging.
The light source adopts the design of dense LED cold light with
uniform luminescence, image cleaning and long service life.
The injection unit adopts high precision injection pump, controlled
by software quantitative and constant speed, stable drop, high
precision;
The sample table adopts 3d manual fine-tuning platform, which is
flexible in operation and accurate in positioning. The sample table
can be customized according to the actual sample size.
The acquisition system adopts a black-and-white imported CCD
camera, which can take stable pictures, make the images clear and
reliable. The lens is equipped with German industrial import
configuration, with adjustable magnification of 0.7-4.5 times and
no distortion in the imaging.
The whole tilting platform adopts software to control tilting with
high precision, with the accuracy as high as 0.01°
The analysis software has a powerful function, with one-button
automatic fitting ability, with the world's most advanced fitting
method, to meet the precise fitting of various liquid droplet
morphology;
Host machine | |
Out size | 800mm(L)*190mm(W)* 640mm(H) |
Weight | 22KG |
Power | 220V / 50,60HZ |
Light source system | |
Light source | Compact LED adjustable blue tone industrial grade cold light source |
Lifelong | Its service life is over 25,000 hours |
Injection unit | |
syringe | Special matching high precision quartz syringe, capacity of 500μL |
dropping liquid | Software control automatic feeding, accuracy up to0.01μL |
Injection unit movement | Up down 50mm; Left right 50mm |
Acquisition system | |
CCD | SONYOriginal imported high-speed industrial chip, 25 frames /S, 130W pixels |
lens | 0.7-4.5 x hd industrial grade continuous variable magnification microscope |
Acquisition system regulation | Front back 100mm (3mm fine tuning), adjustable Angle of view (elevation, top view, 360° rotation and other multi-angle observation) |
Sample table installation | |
Work table size | 160mm*200mm |
Max sample size | 6inch |
Sample table movement | Front back movement manual, stroke 60mm, precision 0.1mm Move about manually, stroke 35mm, precision 0.1mm Move up and down manually, stroke 80mm, precision 0.1mm |
Integral sloping platform | Tilt range±90°,tilt accuracy ±0.01°,Tilt rate adjustable |
Analysis software | |
Contact Angle measurement range | 0-180° |
Accuracy of contact Angle measurement | ±0.1° |
Table interface tension measurement range | 0-2000mN/m |
Table interface tension measurement accuracy | 0.01 mN/m |
Analysis software function | The most advanced contact Angle measurement and analysis software
automatic fitting method (one-click automatic fitting, No human error) includes(Circle method), (Ellipse/Oblique ellipse),Young-lapalace(Differential circle / Differential ellipse); |
Surface free energy | Zisman,OWRK,WU,WU 2,Fowkes,Antonow,Berthelot,EOS,Work of adhesion, work of wetting, coefficient of spreading |
Dynamic contact Angle fitting | Batch screenshot fitting, video continuous automatic fitting, automatic online real-time fitting |
surface/interfacial tension test | Hanging drop method (real-time automatic dynamic surface tension test) |
Test the droplet status | (Pendant Drop),(Sessile Drop)(2/3state)Bubble method, drop method, needle method |
Software communication access | Software with communication interface, support MES upload function. |
Extend the functionality | Multi-group liquid injection expansion, electric/MAGNETIC field working platform, high and low temperature working platform, XYZ AUTOMATIC platform, rotary platform, overall tilt support |
1.GB/T 24368-2009(detection of hydrophobic pollutants on glass
surface);
2.SY/ t5153-2007 (reservoir rock wettability measurement method);
3.ASTM D 724-99 (2003) (test method for surface wettability of
paper);
4.ASTM d5946-2004 (measurement of contact Angle between plastic
film and water);
ISO15989 (measurement of water contact Angle of plastic film and
thin plate corona treatment film);
6. Product features
1. The host adopts high-strength aviation aluminum alloy structure
and modular design concept, independently developed integrated chip
circuit control, adopts the design essence and configuration of the
international top imported contact Angle equipment, to ensure the
instrument has a strong stability;
2. Industrial grade dense adjustable LED cold light source system
(life over 25000H) is adopted to ensure a clearer image and avoid
the volatilization of small droplets caused by extra heat;
5. The first domestic company to provide the contact Angle
measurement and calibration sample imported from Germany to ensure
the precision of the instrument, and the Angle calibration standard
piece 3°5°8°;60 ° 90 ° 120 °;115° (optional);
6. Flexible collection system design, suitable for most of the
measurement environment, simple to cope with a variety of complex
sample surface measurement;
7. Possess the most advanced contact Angle analysis method in the
world, satisfying all kinds of liquid. Accurate fitting of drip imaging,
including the unique differential ellipse of shengding. And differential circle special liquid imaging fitting method;
8. Adopt the international leading calculation method, the software
has realized the full automatic fitting to avoid the error caused
by human operation;
9. Quick fitting function for bilateral contact Angle measurement and
more comprehensive quantitative analysis. Surface wettability of liquids and solids can be analyzed more
accurately. Actual wettability;
10. Dynamic shooting and video fast test data, which can
continuously record the change of test contact Angle, and then
automatically batch fit by the software;
11. Software automatically generates reports, which cover Word form, Excel form, spectrogram. Various forms of data reports;
12. With a variety of optional functional parts, our r & d team is
strong enough to meet various customized measurement requirements
put forward by customers;
13. With the function of forward and backward Angle measurement, it
is convenient for the most efficient measurement of sample surface
stability;
14. Equipped with the rolling Angle measurement function, which can
intelligently distinguish the sliding point of material surface and
the forward and backward Angle measurement in this way;
![]() |