Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Model Number : | LR-SDP-300 |
Brand Name : | Lonroy |
Price : | Negotiable |
Delivery Time : | 5-8 work days |
Supply Ability : | 200 |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union |
ASTM D5946 Portable Contact Angle Tester Surface Energy Tester Goniometer
1. Summary
The contact angle refers to the tangent line of the gas-liquid
interface formed by the intersection of gas, liquid, and solid,
that is, the Angle θ between the liquid surface and the
solid-liquid boundary. The measurement of contact angle is
currently the main method for surface performance testing.
The LR-SDP-300 handheld contact angle measuring instrument uses
optical imaging principles to measure the contact angle, moisture
content, surface energy and other properties of sample surfaces
through image contour analysis methods. The handheld contact angle
measuring instrument is a specialized instrument suitable for
outdoor and large-scale sample surface performance testing. The
instrument is small in size, easy to carry, cost-effective, with
high measurement accuracy and accurate low angle testing.
Contact angle measuring instruments are widely used in various
industries, such as mobile phone manufacturing, glass
manufacturing, surface treatment, material research, chemical
engineering, semiconductor manufacturing, coating ink, electronic
circuits, textile fibers, medical biology, etc. Contact angle
measurement has become an important instrument for evaluating
surface properties.
(Some test functions need special accessories to be purchased)
1. The wetting behavior of liquid on solid surface such as
spreading, penetration and absorption, and the static contact Angle
is measured by the block drop method;
2. Forward Angle, backward Angle, contact Angle lag, rolling Angle
and dynamic contact Angle measurement of material on solid surface;
3. Continuous real-time research and process recording of absorbing
materials, and curve analysis of contact Angle change with time;
4. Measurement of contact Angle of various special materials, such
as powder, curved surface, superhydrophobic/superhydrophilic
samples;
5. Suspension drop method to measure the interfacial tension and
its polarity and dispersion components of various liquid surfaces;
6. Calculate the Surface free energy of solid and analyze its polar
dispersion component;
7. Analyze the adhesion energy of liquid on solid surface and
evaluate the uniformity and cleanliness of solid surface.
3. Instrument introduction
As shown in the figure above, the contact Angle measuring
instrument is mainly composed of light source, injection unit,
acquisition system and analysis software. The equipment adopts the
principle of optical imaging.
The light source adopts intensive LED cold light design, uniform luminous, image
cleaning, long life;
Injection unit adopts manual knob type precise drip, drip stable, high precision;
The acquisition system adopts miniature industrial microscope, CCD camera imported from
Japan, stable shooting, clear image, true and reliable, lens adopts
German industrial import configuration, imaging without distortion;
The analysis software is powerful, with one-button automatic fitting ability, with the
world's leading fitting method, to meet the precise fitting of
various droplet forms;
4. Specifications
Host Machine | |
Outside size | 135mm(Length)*72mm(Width)* 120mm(Thickness) |
Weight | 1.16KG |
Power | 220V / 60HZ |
Light Source System | |
Light source | Intensive dedicated LED adjustable white tone industrial grade cold light source |
Lifetime | Service life of more than twenty-five thousand hours |
Injection Unit | |
Syringe | Special high precision quartz syringe, capacity 250μL |
drip | Manual control of liquid feeding, precision up to 0.2μL |
Injection unit movement | Up down 20mm; Left right 15mm |
Acquisition system | |
CCD | SONY imported high speed industrial grade chip, 25 frames /S, 130W pixel |
Lens | Micro hd industrial grade microscope |
Acquisition system adjustment | 5mm fine tuning, adjustable Angle of view (horizontal, overlooking, elevation and other multi-angle observation) |
Analysis software | |
Measuring range of contact Angle | 0-180° |
Contact Angle measurement accuracy | ±0.1° |
Surface tension measurement range | 0-2000mN/m |
Surface tension measurement accuracy | 0.01 mN/m |
Analyzing software functions | 1,The most advanced contact Angle measurement and analysis software
automatic fitting method (one key automatic fitting, There is no manual error) including(Circle method),(Ellipse/Oblique ellipse),LY,(Differential circle / Differential ellipse); 2,Dynamic contact Angle fitting (batch fitting of multiple images) includes: (Wettability),(Video analysis) (Surface energy) (Surface tension) (Adhesion work) |
5. Accord with national standards
1. GB/T 24368-2009(detection of hydrophobic contaminants on glass
surface);
2. SY/T5153-2007 (method for determination of wettability of
reservoir rocks);
3. ASTM D 724-99 (2003) (Test Method for Surface Wettability of
Paper);
4. ASTM D5946-2004 (Measurement of Contact Angle between Plastic
Film and water);
5. ISO15989 (Measurement of water contact Angle of plastic film and
thin plate corona treated film);
6. Product features
1. The host machine adopts high-strength aviation aluminum alloy
structure with modular design concept, independently developed
integrated chip circuit control, adopted the international top
imported contact Angle equipment design essence and configuration,
to ensure that the instrument has a strong stability;
2. The only manufacturer of hand-held contact Angle measuring
instrument to solve the problem of low Angle fitting, the equipment
is small in size and easy to carry, and the first choice of outdoor
conventional sample surface wettability test;
3. Industrial intensive adjustable LED cold light source system
(life above 25000H), to ensure clearer imaging, while avoiding the
evaporation of small droplets caused by extra heat;
4. High performance Japanese original imported industrial movement,
micro industry Level microscope, the basic image can be achieved without
distortion, to ensure the best imaging effect;
5. USB2.0 standard interface, fast data transmission speed, high
compatibility, strong imaging stability;
6. The first in China to provide Germany imported contact Angle
measurement calibration sample, to ensure the precision of the
instrument, Angle calibration standard piece 3°5°8°; 60 ° 90 ° 120
°; 115° (optional)
7. The acquisition system is designed flexibly and can be used in
most measurement environments
8. With the world's most advanced contact Angle analysis method, to
meet all kinds of liquid
9. Accurate fitting of drop imaging, including the unique
differential ellipse of Special liquid imaging fitting method with
differential circle;
10. Using the international leading calculation method, the
software has realized automatic fitting to avoid the error caused
by human operation;
11. With quick fitting function of bilateral contact Angle
measurement, more comprehensive quantitative analysis,Liquid and
solid surface wettability, more accurate analysis of the surface
actual wetting
12. Dynamic shooting and video fast test data, which can
continuously record the change of test contact Angle, and then the
software automatically fits in batches;
13. Software automatically generates reports which are covered Word form, Excel form, spectrogram
Forms and other data reports;
![]() |