Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Model Number : | LR-O032 |
Price : | USD 1000-3000 |
Brand Name : | Lonroy |
Supply Ability : | 200 pieces |
Delivery Time : | 5-8 work days |
ASTM D664 ASTM D2896 Auto Petroleum Product Total Acid and Base
Value Tester TAN TBN Potentiom Titration Method
1. Product Introduction
GSSZ-V Alkalinity Automatic Titrator adopts the principle of
potentiometric titration. Under computer control, it realizes
automatic and visualized data processing of titration process.
Different electrodes can be used for acid-base neutralization
titration, precipitation titration, redox titration, complexation
titration, non-aqueous titration (such as determination of
mercaptan sulfur, acid (base) value in petrochemical oil products;
acid value (acid value) in the food industry; acid value (acid
value) in resins in the chemical industry) and other titrations;
the instrument adopts imported titration unit to smooth the
titration curve and correct the titration end point position to
ensure the accuracy of the results. It is an essential instrument
for petrochemical laboratories, analysis rooms and scientific
research departments.
2. Reference standard
SH/T 0251-1993 (2004 confirmed version) Petroleum product base
number determination method complies with GB/T264-1983 and covers
GB/T7304-2000 standard
GB/T 6909.1 "Analysis method for boiler water and cooling water
Determination of hardness High hardness"
GB/T 6909.2 "Analysis method for boiler water and cooling water
Determination of hardness Low hardness" analysis method.
GBT 7304 Determination of acid value of petroleum products
Potentiometric titration method
GB/T 18609 Determination of acid value of crude oil (potentiometric
titration method)
GB/T 264 Determination of acid value of petroleum products
GB/T 258 Determination of acidity of light petroleum products
GB/T 12574 Determination of total acid value of jet fuel
Meet the corresponding ASTM D2896, ASTM D4739, ASTM D664, ASTM
D7946
3. Product Features
1. Imported titration device is used. The computer operation is
highly automated and the analysis results are accurate.
2. Automatic cleaning, automatic refilling, fixed value addition,
and electromechanical are organically combined.
3. Dual high-resistance input, automatic endpoint judgment,
automatic filtering of false endpoints, and stable and reliable
electrode potential.
4. The titration curve (E-V) and the first-order derivative curve
(DE/DV) are displayed in real time, the titration process is
intuitive and clear, and the curve automatically scrolls when it
exceeds the boundary.
5. Dynamic equivalence point titration (DET), equivalent
equivalence point titration (MET), preset endpoint potentiometric
titration (SET), pH correction (CAL), pH measurement (MEAS).
4. Product Parameters
1. Measuring range | mV: -2000.0~2000.0mV pH: 0~20.000pH |
2. Resolution | mV: 0.1mV; pH: 0.001pH |
3. Electronic unit error | mV: ±0.03%FS± 1 word pH: ±0.001pH ± 1 word |
4. Electronic unit input impedance | ≥3*1012Ω |
5. Electronic unit input current | ≤ 1*10-12A |
6. Electronic unit stability | ±0.3 mV± 1 Words/8h |
7. Burette volume | 10mL |
8. Minimum sending volume | 0.001mL |
9. Burette capacity allowable error (accuracy) | ±0.020mL |
10. Burette infusion or refilling speed | 55±5s/full tube |
11. Titration endpoint repeatability error | ≤0.2% (0.1mol/L HCL titrates 0.1mol/L NaOH) |
![]() |