Sign In | Join Free | My himfr.com
Home > Film Testing Equipment >

Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765

DONGGUAN LONROY EQUIPMENT CO LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765 from wholesalers
     
    Buy cheap Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765 from wholesalers
    • Buy cheap Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765 from wholesalers
    • Buy cheap Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765 from wholesalers

    Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765

    Ask Lasest Price
    Model Number : LR-F062
    Brand Name : Lonroy
    Price : Negotiable
    Supply Ability : 200
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765

    ASTM D1709 ISO 7765 Falling Dart Impact Tester For Plastic Film

    1. General Details
    Apply to the national standard and international standard
    Mechanical modelling is novel, Considerate operation design
    2 test methods of A & B and automatic determination of testing status
    It is convenient and efficient for user's operation with the unique observation light.
    Micro computer processing test results
    Test data are processed by microcomputer.
    with Intelligent test process, greatly improving the working efficiency
    Sample pneumatic clamping and releasing reduce the errors and time.
    Test process without manual drawing, data parameters would be displayed on the LCD

    2. Principle & Standards
    Principle
    Before starting the test, choose test method, and estimate an initial mass and Δm. Start the test. If the first specimen fails, decrease the mass of the falling dart by Δm. If the first specimen is not a failure, increase the mass of the falling dart by Δm. Continue the test according to this rule. In brief, increase or decrease by Δm according to whether the former specimen is a failure or not. After 20 specimens, calculate the total number of failed specimens N. If N equals to 10, the test is over. If N is less than 10, add specimens and continue to test until N equals to 10. If N is greater than 10, add specimen and continue the test until the number of non-failure specimens reaches 10. Then the tester calculates the test results automatically according to specific formulas.
    Standards
    GB/T 9639.1-2008,ISO 7765-1-1988, ASTM D1709,JIS K7124-1


    3. Applications Specifications

    Basic Applications
    • Impact resistance test of plastic films, sheets and composite films e.g. PE preservative films, wrapping films, PET sheets and other food package and heavy packages
    • Impact resistance test of aluminum foils and aluminum plastic composite films
    • Impact resistance test of paper and paper board
    Extended ApplicationsTest the resistance of the specimen against the falling ball. Mount the specimen on specific clamp for falling ball impact test and select falling ball of certain weight for the impact test. Check the status of the specimen and determine the
    impact resistance of the specimen
    Impact test of shoulder lining. Mount the shoulder lining specimen to the specified clamp and select falling dart of certain weight for impact test. Check the status of the specimen and determine the impact resistance of the shoulder
    lining specimen.
    Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765

    4. Technical Specifications

    Test MethodMethod A or Method B or AB Methods is optional
    Test RangeMethod A: 50~2000 g
    Method B: 300~2000 g
    Accuracy0.1 g (0.1J)
    Impact heightA methods:660mm B methods 1500mm
    Dart head diameterA methods:38mm B methods:50mm
    Specimen ClampPneumatic Clamp
    Pressure of Gas Supply0.6 MPa (outside of supply scope)
    Port of Gas SupplyΦ8 mm PU Tubing
    Specimen Size> 150 mm x 150 mm
    Power SupplyAC 220V 50Hz
    Net Weight70 kg
    Out Size:A methods:L500*W450*H1320mm
    B methods:L500*W450*2160mm
    Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765

    Standard configuration
    Method A Accessories and Micro Printer
    Optional Parts
    Method B Accessories, Professional Software and Communication Cable

    Quality Laboratory Falling Dart Impact Tester For Plastic Film ASTM D1709 ISO 7765 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN LONROY EQUIPMENT CO LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)