Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | Lonroy |
Model Number : | BGD 452 |
Certification : | Includes Calibration Certification |
Price : | Negotaible |
Payment Terms : | L/C,D/A,D/P,T/T,Western Union |
Supply Ability : | 200 |
Delivery Time : | 5-8 work days |
BGD 452 ASTM D 2354 Minimum Film-Forming Temperature Tester Mfft Testing Machine
1.Description
Emulsions for coatings and polymer dispersions for coatings and
plastics, as an important part of coatings, adhesives and other
polymer materials, their film-forming properties directly affect
the drying properties of the final product, so it is very necessary
to understand its minimum film-forming temperature.
Emulsion or dispersion material uniformly dispersed in a liquid
medium (usually water) in the formation of the dispersion system,
in the drying process, due to liquid evaporation can be prompted by
inter-particle interactions, so that tightly combined. If the
temperature is not high enough to make the polymer particles
polymerization, the polymer particles are no longer agglomerated
together, thus forming intermittent opaque white lumps; if the
temperature conditions are sufficient to make the polymer particles
polymerization, then the particles agglomerated together, then the
formation of a continuous and uniform transparent film.
White Point Temperature: The temperature at which an opaque film is
transformed to form a transparent film.
Minimum Film Formation Temperature: The lowest temperature at which
a continuous, uniform, crack-free, transparent film can be formed
(the white point temperature is generally a few degrees lower than
the minimum film formation temperature).
BGD 452 Minimum Film-Forming Temperature Tester is a newest
instrument developed by BGD, whose main structure is a metal
gradient plate, and the two ends of the gradient plate are set up
with refrigeration source and heating source respectively. Through
the principle of metal heat conduction, different temperature
gradients are generated on the metal plate. In the temperature
gradient plate coated with a continuous uniform thickness of the
emulsion or polymer dispersion of the wet film, dry air flow drying
samples, samples at the same time by the gradient plate temperature
evaporation of water and film. Due to the different temperatures on
the gradient plate and the different positions of the sample film
formation, to find the junction of the formation of a continuous
transparent film and white opaque (unpolymerized), this point
corresponds to the temperature on the gradient plate can be derived
from the screen display, the temperature is the MFT temperature of
the sample.
The instrument meets the standards of GB/T 9267, ISO 2115 and ASTM
D2354; it can determine the minimum film forming temperature of
polymer emulsion simply, intuitively and accurately.
Characteristics:
* High-tech products, the first of its kind in China, incorporating a
number of patents with independent property rights;
* Small size, high precision, intelligent operation, simple and
convenient.
* Color touch screen + menu operating system, multiple parameters
real-time display, simple and convenient operation
* High-precision digital temperature sensor to ensure that the
temperature error is less than ± 1 ºC.
* Standard with independent cooling water circulation system
* Optional dry air generator, can produce low dew point dry air, can
make the sample completely dry and test results are not affected by
environmental humidity.
* Movable scale (with lighting) to facilitate the experimenter to
read out the temperature at any point on the gradient plate: the
operator can move the scale arbitrarily, the instrument
automatically recognizes the current position point of the scale
and displays the real-time temperature of the position on the LCD
screen.
* Automatic monitoring of the cooling water temperature and flow, if
there are abnormalities in the alarm and automatic shutdown
* Workbench (gradient plate) using copper surface special process,
fast heat conduction, strong stability
* The system automatically reminds the test process
* Seven test conditions can be selected to facilitate the testing of
different film temperature samples
* Gradient plate uniformly distributed 16 high-precision temperature
sensors.
* Standard with a special preparator (gap depth of 100μm/170μm), the
sample can be coated into a thickness of about 100 μm, the width of
22mm continuous and uniform wet film.
2.Technical Parameter
Working temperature range of gradient platen | -10ºC~+90ºC (When cooled by common tap water) |
Number of inspection points of gradient platen | 16 points |
Interval distance of gradient | 20mm |
Test channels | 6 pcs (width is 22mm) |
Gradient platen size | 447mm × 210mm |
Power Supply | 220V/50Hz AC wide voltage (three-phase supply with good earth) |
Tester Size | 600mm (L) × 450mm (W) × 300mm (H) |
Chiller Size | 560mm (L) × 240mm (W) × 200mm (H) |
Dry Air Generator | 555mm (L) × 255mm (W) × 525mm (H) |
Net Weight | 26KG (Excludes Cooling water tank and Dry Air Generator) |
Power | 750W |
Ordering Information | BGD 452---Minimum Film-Forming Temperature Tester |
![]() |